CISCOATMPVCTRAPEXTNMIB

Children

class ydk.models.cisco_ios_xe.CISCO_ATM_PVCTRAP_EXTN_MIB.CISCOATMPVCTRAPEXTNMIB

Bases: Entity

Class Hierarchy : CISCOATMPVCTRAPEXTNMIB

This class represents state data.

catmcurstatchangepvcltable

A table indicating all VCLs for which there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and atmVclOperStatus to have changed in the last corresponding PVC notification

type: CatmCurStatChangePVclTable

config: False

catmstatuschangepvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and atmVclOperStatus to have changed in the same direction in the last corresponding PVC notification

type: CatmStatusChangePVclRangeTable

config: False

catmsegccstatuschpvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and atmVclOperStatus to have changed due to segment CC failure in the same direction in the last PVC corresponding notification

type: CatmSegCCStatusChPVclRangeTable

config: False

catmendccstatuschpvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and atmVclOperStatus to have changed due to End CC failure in the same direction in the last PVC notification interval

type: CatmEndCCStatusChPVclRangeTable

config: False

catmaisrdistatuschpvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and atmVclOperStatus to have changed due to AIS/RDI failure in the same direction in the last corresponding PVC notification

type: CatmAISRDIStatusChPVclRangeTable

config: False

catmdownpvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and atmVclOperStatus to have detected as Down in the last corresponding PVC notification

type: CatmDownPVclRangeTable

config: False

catmcurstatusuppvcltable

A table indicating all VCLs for which there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and atmVclOperStatus to have changed to UP in the last corresponding PVC notification

type: CatmCurStatusUpPVclTable

config: False

catmstatusuppvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and loopback OAM status to have detected as recovered in the last corresponding PVC notification

type: CatmStatusUpPVclRangeTable

config: False

catmsegccstatusuppvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and Segment CC OAM status to have detected as recovered in the last corresponding PVC notification

type: CatmSegCCStatusUpPVclRangeTable

config: False

catmendccstatusuppvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and End-to-End CC OAM status to have detected as recovered in the last corresponding PVC notification

type: CatmEndCCStatusUpPVclRangeTable

config: False

catmaisrdistatusuppvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and AISRDI OAM status to have detected as recovered in the last corresponding PVC notification

type: CatmAISRDIStatusUpPVclRangeTable

config: False

catmuppvclrangetable

A table indicating more than one VCLs in a consecutive range and for each VCL there is an active row in the atmVclTable having an atmVclConnKind value of `pvc’ and atmVclOperStatus to have detected as Up in the last corresponding PVC notification

type: CatmUpPVclRangeTable

config: False